Support homeCell RangerAnalysis
Antigen Capture or Barcode Enabled Antigen Mapping (BEAM) with Cell Ranger multi

Antigen Capture or Barcode Enabled Antigen Mapping (BEAM) with Cell Ranger multi

The Chromium Single Cell 5’ Barcode Enabled Antigen Mapping (BEAM) technology offers a scalable approach for mapping a V(D)J receptor to a target antigen by enabling the detection of gene expression profiles, paired V(D)J receptors, and signal from a bound antigen from the same single cell. All of these libraries, generated from a single GEM well, can be analyzed together with Cell Ranger v7.1 or later using the cellranger multi pipeline.

Important
BEAM is unsupported with GEM-X chemistry; therefore, Cell Ranger does not support BEAM/Antigen Capture libraries produced with this chemistry.

Hereafter libraries created using the BEAM-T workflow are called TCR Antigen Capture libraries, whereas libraries created using the BEAM-Ab workflow are called BCR Antigen Capture libraries. Antigen Capture without a prefix refers to either TCR or BCR Antigen Capture library, depending on the context.

To analyze an antigen library created using an antigen-multimer staining assay (TotalSeq™-C, Immudex's dMHC Dextramer® libraries with dCODE Dextramers), visit the TotalSeq™-C section of the Feature Reference CSV page.


Important
Antigen Capture (BEAM) analysis is not supported on the 10x Genomics Cloud Platform.
Important
Antibody Capture (cell surface protein) Feature Barcode libraries can also be generated and analyzed with Gene Expression, Antigen Capture, and V(D)J libraries. See the example config CSV section to include an Antibody Capture library in your analysis.
Important
Antigen Capture and CRISPR Guide Capture cannot be performed in the same experiment.

Antigen Capture + VDJ + Gene Expression (GEX) is the minimum set of libraries necessary to process antigen data from a single experiment. Here is a list of supported and unsupported library combinations. Please note that this table is not an exhaustive list.

Library CombinationSupported?
TCR Antigen Capture + VDJ-T + GEXYes
BCR Antigen Capture + VDJ-B + GEXYes
Antigen Capture + VDJ + GEX + Antibody CaptureYes
TCR Antigen Capture + VDJ-T-GD + GEXEnabled but unsupported
Antigen Capture onlyNo
Antigen Capture + VDJNo
TCR Antigen Capture + BCR Antigen CaptureNo
Antigen Capture + CRISPR Guide CaptureNo

The following inputs are needed to analyze Antigen Capture, V(D)J, and Gene Expression libraries together using the cellranger multi pipeline:

Any Cell Ranger workflow starts by demultiplexing the Illumina sequencer's base call files (BCLs) for each flow cell directory into FASTQ files. Follow the instructions on running Illumina's BCL convert, or bcl2fastq to generate Gene Expression, V(D)J, and Antigen Capture FASTQ files. If you are already starting with FASTQ files, you can skip this step.

A Feature Reference CSV file is required when processing any Feature Barcode data.

If a TCR Antigen Capture library is present, the Feature Reference must have an additional column, mhc_allele, that defines the MHC allele associated with each antigen included in the experiment.

id,name,read,pattern,sequence,feature_type,mhc_allele ag1,ag1,R2,^(BC),CGATGCCGGACGATC,Antigen Capture,A*01 ag2,ag2,R2,^(BC),CCGTCTCACCGATAT,Antigen Capture,A*01 neg_control01,neg_control01,R2,^(BC),GATTGGCTACTCAAT,Antigen Capture,A*01 ag4,ag4,R2,^(BC),CGGCTCACCGCGTCT,Antigen Capture,A*02 ag5,ag5,R2,^(BC),CTATCTACCGGCTCG,Antigen Capture,A*02 neg_control02,neg_control02,R2,^(BC),CATGTCTACGTTAAG,Antigen Capture,A*02 ab1,ab1,R2,^(BC),GAGGTACACCAATCA,Antibody Capture,

If one Antigen Capture id has an entry in the mhc_allele column, all IDs must have an entry in that column. The mhc_allele name for the negative control peptide must match the name specified in the [antigen-specifity] section of the multi config CSV. Similarly, the id field for the control antigen in the Feature Reference CSV must match the control_id in the multi config CSV.

For BCR Antigen Capture, the mhc_allele column must NOT be included:

id,name,read,pattern,sequence,feature_type ag1,ag1,R2,^(BC),CGATGCCGGACGATC,Antigen Capture ag2,ag2,R2,^(BC),CCGTCTCACCGATAT,Antigen Capture ag4,ag4,R2,^(BC),CGGCTCACCGCGTCT,Antigen Capture ag5,ag5,R2,^(BC),CTATCTACCGGCTCG,Antigen Capture ag6,ag6,R2,^(BC),CATGTCTACGTTAAG,Antigen Capture ag7,ag7,R2,^(BC),GAGGTACACCAATCA,Antigen Capture ag8,ag8,R2,^(BC),AGCACGACCTTGGTT,Antigen Capture neg_control01,neg_control01,R2,^(BC),GATTGGCTACTCAAT,Antigen Capture

The id field for the control antigen in the Feature Reference CSV must match the control_id in the multi config CSV.

Loupe V(D)J Browser v5.0 and Loupe Browser v6.4 extract antigen names from the Feature Reference CSV. These names cannot be changed via the browser interface. In this Feature Reference example, the id and name fields have the same entry for each antigen. In Loupe Browser, the name field corresponds to the antigen name in grey (as shown below):


The Feature Barcode sequences of available BEAM conjugates section lists all the BEAM conjugate Feature Barcode sequences.

BEAM ConjugateSequence
BEAM Conjugate 1CGATGCCGGACGATC
BEAM Conjugate 2CCGTCTCACCGATAT
BEAM Conjugate 3GATTGGCTACTCAAT
BEAM Conjugate 4CGGCTCACCGCGTCT
BEAM Conjugate 5CTATCTACCGGCTCG
BEAM Conjugate 6CATGTCTACGTTAAG
BEAM Conjugate 7GAGGTACACCAATCA
BEAM Conjugate 8AGCACGACCTTGGTT
BEAM Conjugate 9TAGTATCTATAGATC
BEAM Conjugate 10TCTGAGTATCAATTG
BEAM Conjugate 11CCGAGTGACGATGTG
BEAM Conjugate 12CCGAACGCAGCCGTA
BEAM Conjugate 13TATCCATATACAGGA
BEAM Conjugate 14AATAATCTTGCGCTT
BEAM Conjugate 15CTTGCATGTAATGTA
BEAM Conjugate 16CGTCCTCGACTGTCC

The cellranger multi pipeline requires a configuration CSV file as input, referred to here as the multi config CSV. The multi config CSV contains paths to FASTQ files for V(D)J, Gene Expression, and Antibody Capture (BEAM) libraries, as well as a path to the Feature Reference CSV.

Main sections in a multi config CSV:

The multi config CSV contains both the library definitions and experiment configuration variables, comprising up to five sections: - [gene-expression] - [feature] - [vdj] - [antigen-specificity] - [libraries]

Go to the Cell Ranger Multi Config CSV page for a complete list of options for each section.

Go to the Cell Ranger Multi Config CSV page for a complete list of options for each section.

Example multi config CSVs can be downloaded from public datasets. Cell Ranger v7.1 and later also provides the option to download a multi config CSV template via the command line.

Here are the example multi config CSVs for a few commonly used library combinations with Antigen Capture. Make sure to replace /path/to with the full path to your data, and customize the experiment's sample/library/file names.

[gene-expression] reference,/path/to/transcriptome create-bam,true [vdj] reference,/path/to/vdj_reference [feature] reference,/path/to/feature_ref.csv [antigen-specificity] control_id, neg_control, [libraries] fastq_id,fastqs,lanes,feature_types,subsample_rate GEX_fastqs_id,/path/to/GEX_fastqs,1|2,Gene Expression, VDJ_B_fastqs_id,/path/to/vdj_B_fastqs,1|2,VDJ-B, BEAM_fastqs_id,/path/to/Ag_fastqs,1|2,Antigen Capture,
[gene-expression] reference,/path/to/transcriptome create-bam,true [vdj] reference,/path/to/vdj_reference [feature] reference,/path/to/feature_ref.csv [antigen-specificity] control_id,mhc_allele neg_control01,A*01 neg_control02,A*02 [libraries] fastq_id,fastqs,lanes,feature_types,subsample_rate GEX_fastqs_id,/path/to/GEX_fastqs,1|2,Gene Expression, VDJ_T_fastqs_id,/path/to/vdj_B_fastqs,1|2,VDJ-T, BEAM_fastqs_id,/path/to/Ag_fastqs,1|2,Antigen Capture,
[gene-expression] reference,/path/to/transcriptome create-bam,true [vdj] reference,/path/to/vdj_reference [feature] reference,/path/to/feature_ref.csv [antigen-specificity] control_id,mhc_allele neg_control01,A*01 neg_control02,A*02 [libraries] fastq_id,fastqs,lanes,feature_types,subsample_rate GEX_fastqs_id,/path/to/GEX_fastqs,1|2,Gene Expression, VDJ_B_fastqs_id,/path/to/vdj_B_fastqs,1|2,VDJ-B, BEAM_fastqs_id,/path/to/BEAM_fastqs,1|2,Antigen Capture, Antibody_fastqs_id,/path/to/AB_fastqs,1|2,Antibody Capture,

Generate a multi config CSV template by running cellranger multi-template, see usage here.

These images highlight the relationship between a TCR Antigen Capture Feature Reference CSV and its multi config CSV:


Go back to the Cell Ranger multi page to learn more about running cellranger multi.